Regulatory Compliance Screening

 

 

Cypher Scientific uses only the most advanced and accurate test environments for verification of regulatory compliance. UL, FCC, CUL, FAA, FDA, and a host of other certification programs are available depending on your product type and target markets. Here is a partial list of testing that can be executed in our labs:

 

Radiated and Conducted Emissions
Electrostatic Discharge (ESD) Radiated Immunity EFT/Burst Surge
Immunity to Conducted Disturbances
Radiated and Conducted Emissions:
FCC Part 15 Subpart B, using ANSI C63.4:2009; ANSI C63.10;
FCC Part 18, using MP-5;
CISPR11; AS/NZS CISPR 11; IEC/EN 55011; CNS 13803 (CISPR 11); CISPR 13; EN 55013; CNS 13439 (CISPR 13);
CISPR 14-1; CISPR-14-2; EN 55014;
EN 50083-1; EN 50083-2;
CISPR 22; AS/NZS CISPR 22; EN 55022; ICES-001; ICES-003; ICES-005;
ANSI C63.17; ANSI/TIA-603-C-2004
Electrostatic Discharge (ESD): IEC/EN 61000-4-2
Radiated Immunity: IEC/EN 61000-4-31 (up to 10V/m @ 1 GHz, and 3V/m @ 2.7 GHz)
EFT/Burst: IEC/EN 61000-4-4
Surge: IEC/EN 61000-4-5
Immunity to Conducted Disturbances: IEC/EN 61000-4-6
Power Frequency Magnetic Field Immunity: IEC/EN 61000-4-8
Voltage Dips, Short Interruptions and Line Voltage Variations: IEC/EN 61000-4-11
Current Harmonics: IEC/EN 61000-3-2
Flicker: IEC/EN 61000-3-3
Product Family Standards: ITE; EN 55024; CISPR 24
Laboratory: IEC/EN 61326
Maritime: IEC/EN 60945 (2002), (only paragraphs 9 and 10)
Medical: IEC/EN 60601-1-2
Product Safety – Information Technology Equipment – Safety – Part 1: General requirements
EN 60950-1:2006; IEC 60950-1:2005 on single phase equipment (Except sections 2.1.1.9, 2.3.1, 2.3.4, 2.3.5, 2.10.3.9 , 2.10.4,2.10.5, 2.10.7, 2.10.8, 4.2.8, 4.3.6, 4.3.12, 4.3.13, 4.6.2, 4.6.5, 4.7.3, 6.2.2.1, 7.4.2); AS/NZS 60950.1 2011
EMC for Radio Equipment :
EN 301 489-1 (excluding section 9.6);
EN 301 489-2, -3, -4, -5, -6, -7, -9, -10, -11, -12, -13, -14, -15; EN 301 489-16, -17, -18, -19, -20, -22, -28

 

Generic Standards:
Industrial
EN 61000-6-1, -2, -3, -4
47 CFR (FCC)
Parts: 2, 11, 15, 22, 24, 25, 27, 74, 80, 87, 90, 95, 97, 101 (excluding SAR and DFS Testing)

 

Canada:
CUL
Radio Standards Specifications in Category I (IC)
RSS-102; RSS-111; RSS-112; RSS-117; RSS-118; RSS-119; RSS-123; RSS-125; RSS-127; RSS-129; RSS-131; RSS-132; RSS-133; RSS-134; RSS-135; RSS-136; RSS-137; RSS-138; RSS-139; RSS-141; RSS-142; RSS-170; RSS-181; RSS-182; RSS-191; RSS-192; RSS-194; RSS-195; RSS-196; RSS-197; RSS-199; RSS-210; RSS-213; RSS-215; RSS-220; RSS-243; RSS-287;RSS-288; RSS 310; RSS Gen

 

Europe:
(Radio Telecommunications) (RF sections Only)
ETSI EN 300 086; ETSI EN 300 113; ETSI EN 300
ETSI EN 300 162-1; ETSI EN 300 162-2; ETSI EN
ETSI EN 300 219-1; ETSI EN 300 219-2; ETSI EN
ETSI EN 300 220-2; ETSI EN 300 220-3; ETSI EN
ETSI EN 300 296-1; ETSI EN 300 296-2; ETSI EN
ETSI EN 300 330-1; ETSI EN 300 330-2; ETSI EN
ETSI EN 300 373-1; ETSI EN 300 373-2; ETSI EN
ETSI EN 300 390-2; ETSI EN 300 440-1; ETSI EN
ETSI EN 300 422-1; ETSI EN 300 422-2; ETSI EN
ETSI EN 300 454-1; ETSI EN 300 454-2; ETSI EN
ETSI EN 300 720-2; ETSI EN 301 357; ETSI EN 301 357-1; ETSI EN 301 357-2; ETSI EN 301 441; ETSI EN 301 443; ETSI EN 301 444; ETSI EN 301 473; ETSI EN 301 489-32; ETSI EN 301 502; ETSI EN 301 511 (only section 4);
ETSI EN 301 840-1; ETSI EN 301 840-2; ETSI EN 301 843-1; ETSI EN 301 843-4; ETSI EN 301 843-5; ETSI EN 301 843-6; ETSI EN 301 893; ETSI EN 302 064-1; ETSI EN 302 064-2;162;300 162-3; 300 220-1; 300 224; 300 328; 300 341; 300 390-1; 300 440-2; 300 454/A1; 300 720-1;
ETSI EN 302 066-1; ETSI EN 302 066-2;
ETSI EN 302 194-1; ETSI EN 302 194-2;
ETSI EN 302 208-1; ETSI EN 302 208-2; ETSI EN 302 217-1; ETSI EN 302 217-2-2; ETSI EN 302 217-3; ETSI EN 302 291-1; ETSI EN 302 291-2; ETSI EN 302 326-1; ETSI EN 302 326-2; ETSI EN 303 035-1; ETSI EN 303 035-2

 

Hong Kong (HKCA):
HKCA 1001; HKCA 1002; HKCA 1003; HKCA 1004; HKCA 1005; HKCA 1006; HKCA 1007; HKCA 1008; HKCA 1010; HKCA 1016; HKCA 1035; HKCA 1036; HKCA 1037; HKCA 1039; HKCA 1041; HKCA 1042; HKCA 1044; HKCA 1045; HKCA 1046; HKCA 1048; HKCA 1049; HKCA 1051 (excluding DFS Testing)

 

Australia: Harmonized
AS/NZS 4295:2004; AS/NZS 4365:2002; AS/NZS 4415.1:2003; AS/NZS 4415.2.2003/Amdt 1:2004; AS/NZS 4330:2000; AS/NZS 4280:1995; AS/NZS 4280.1:2003/Amdt 1:2005; AS/NZS 4280.2:2003/Amdt 1:2005;
AS/NZS 4583:1999/Amdt 1:2000/Amdt 1:2005;
AS/NZS 4769.1:2000; AS/NZS 4769.2:2000; AS/NZS 4582:1999
Australia: Non-Harmonized
AS/ACIF S042.1; AS/ACIF S042.3; AS/NZS 4268:2008; AS/NZS 4281:2007; AS/NZS 4355:2006; AS 4367:2007; AS/NZS 4771:2000/Amdt 1:2003

 

Taiwan:
LP0002

 

Singapore:
IDA TS GSM-MT (only RF requirements, section 2.3); IDA TS EMC; IDA TS RPG; IDA TS SRD; IDA TS WBA

 

Japan:
Agreement of VCCI V-3

 

Japan Radio
ARIB STD-T66; ARIB STD-T67

 

Korea
Republic of Korea Conformity Assessment Procedure for Electromagnetic Susceptibility (RRA Announce 2012-22, June 28, 2012);
Technical Requirements for Electromagnetic Susceptibility (RRA Public Notification 2012-14, June 28, 2012)
Korean Standard
KN 61000-4-2 KN 61000-4-3 KN 61000-4-4 KN 61000-4-5 KN 61000-4-6 KN 61000-4-8 KN 61000-4-11 KN 60601-1-2 KN 24
KN 41
KN 51
KN 301 489-01 KN 301 489-02 KN 301 489-07 KN 301 489-17 KN 301 489-24

 

Closely Corresponding International Standard
IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-8 IEC 61000-4-11 CISPR 60601-1-2 CISPR 24
EC directive 95/54 (1995-5) IEC 62236-1-5
IEC 301 489-1
IEC 301 489-2
IEC 301 489-7 IEC 301 489-17 IEC 301 489-24
1 Radiated Immunity testing will be performed using an alternative, non-standard, laboratory validated test method based ISO/IEC 61000-4-3.


Did we leave something out?  Contact us... Cypher Scientific’s compliance & regulatory engineering team will help.

What can we build better for you?